282401 / 6125/2121-5501-6011-242  - Stahl Spain  Sales

BRAND Stahl
Product 282401 / 6125/2121-5501-6011-242
Description LED headlight
Internal code 4846837
Technical specification explosion-proof Type: 6125/2121-5501-6011-242 Color temperature: 5,700 K Luminous flux: 24,562 lm Luminaire efficiency: 111 lm/W Light distribution: narrow beam Case material: stainless steel 1.4404 powder-coated double powder-coated Housing color: similar to RAL 9010 Mounting: with bracket, SS316L settled Lens material: reinforced glass Rated operating voltage AC: 110... 277 V Rated operating voltage DC: 196... 250 V Light power: 225 W Dimensions (L x W x H): 520 x 400 x 84 mm Range of use (zones): 1, 2, 21, 22 Gas explosion protection: II 2 G Ex db eb op is IIC T4Gb Dust explosion protection: II 2 D Ex tb op is IIIC T100°C Db Min. ambient temperature: -60 °C Max. ambient temperature: +60 °C Minimum ambient temperature Note: Switch on above -40 °C Protection class (IP): IP66 Lamp type: LED Cable and wire entries: 1 x M25 x 1.5 Sealing plug: 2 x M25 x 1.5 For more information, see: r-stahl.com Webcode 6125A Scope (Conf) ATEX/IECEx Standard language Area of use zone 1 Gas equipment subgroup IIC SS316L lamp design Lamp type LED Extruded heatsink frame size Lamp power_config 225 W Light color 5700 K CRI 70 Light distribution 20° Lens material with Electronic ballast 6040/111-110-11 Bus system without DALI Switch without Through-wiring cross section without Phoenix terminal block installed Number of terminals 5 Terminal description PE + N + L1 + L2 + L3 Ex version Yes Standard packaging Hole type 3XM25 Thermal protection with SS316L frame material Case color double coated RAL 9010 Standard cable and cable entries installation frame with 8290/3-M25 cable entry Cable entry2 8290/3-M25 Cable entry3 without

Please Contact Us to Order to offer competitive prices and delivery time for Stahl - 282401 / 6125/2121-5501-6011-242 LED headlight number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Spain Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Stahl

138406

(blanking plugs f. cable glands Pg9 /M16.....50pcs CCT No.: 39269097 DE Net weigth: 0,061 KG)

138417

(blanking plugs f. multiple cable glands, d 5,5mm...50pcs CCT No.: 39269097 DE Net weigth: 0,031 KG)

239156

Cable gland with reduction sealing insert explosion-protected

138482

8161/5-M16-9 Cable gland Ex e polyamide, 4-9mm, 50 pcs Cable Glands Series 8161, explosion protected Version: 8161/5 Ex e (black) Thread size: M16 x 1.5 Number of entries: 1 Cable dia. range [mm]: 4 ... 9 For use in: Zones 1 & 2, 21 & 22

138520 8161/5-M25-17

(Cable Glandsexplosion-protectedType : 8161/5-M25-17Thread size : M25Thread length : 10 mmMaterial : PolyamideColour : blackClamping range : 7 ... 17 mm2Cable armour : Unarmoured cablesApplication range (Zone) : 1 , 2 , 21 , 22Type of protection (IP) : IP66Gas explosion protection : II 2 G Ex e IIDust explosion protection : II 2 D Ex tD A21Min. ambient temperature : -40 °CMax. ambient temperature : +75 °CCCT No.: 39269097 DENet weigth: 0,020 KG)

143544 8290/3-M25

(Stopping Plug explosion-protected Type : 8290/3-M25 Material : Polyamide Thread size : M25 Drive : Hexagon socket Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e IIC Gb Dust explosion protection : II 2 D Ex tb IIIC Db Min. ambient temperature : -60 °C Max. ambient temperature : +80 °C Packaging unit : 100 CCT No.: 85389099 DE Net weigth: 0,700 KG)

143556 8290/3-M16

(Stopping Plug explosion-protected Type : 8290/3-M16 Material : Polyamide Thread size : M16 Drive : Hexagon socket Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e IIC Gb Dust explosion protection : II 2 D Ex tb IIIC Db Min. ambient temperature : -60 °C Max. ambient temperature : +80 °C Packaging unit : 100 CCT No.: 85389099 DE Net weigth: 0,300 KG)

145280

8491 / 11-230 horn with horn 230V, AC

145285

8491 / 21-230 Flachhupe 230V, AC

150579

8570/12-306 Plug 2P+PE 16A 200-250V, 60+60Hz, 6h, blue

155399

(Push button explosion-protected Type : 8602A0001-1 Enclosure material : Polyamide Seal : Standard Mounting : with threaded Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 Packed : Yes)

155476

(Rotary handle, large, raised explosion-protected Type : 8602A0724-1-ss-0 Enclosure material : Polyamide Seal : Silicone Mounting : with threaded Padlockable in : no position Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -50 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 Packed : Yes)

155785

(Label I O II)

155908

labels buttons series 8003

P/N: 160321, Type: 9170/10-12-21S

Switch amplifier digital input

160321 9170/10-12-21S

IS PAC Isolating Repeater Switching Repeater Field Circuit Ex i explosion-protected Type : 9170/10-12-21s Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Min. nominal voltage : 120 V Max. nominal voltage : 230 V Nominal current : 12 mA Number of channels : 1 Output / channel : 1 change over contact LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Dust explosion protection : II (1) D [Ex ia] IIIC For further information, see : www.r-stahl.com Web code 9170A Switching Repeater Series 9170, Field Circuit Ex i, single channel Basic function: binary / digital input Intrinsically safe input: [Ex ia] IIC Power supply: 120 ... 230 V AC Input: acc. to EN 60947-5-6 (NAMUR) Output / channel: 1 change-over contact Connection type: Screw terminals

167080: 6608/522-9611-7267

(Emergency Strip light for fluorescent lamps Type: 6608 / 5.2-9 ...-... 7 Specifications: Gas explosion: II 3 G Ex nAC II T4 dust explosion protection: II 2 DT 80 ° C test certificate: DMT 03 E 093 / ATEX e 094 x Suitable for: fluorescent lamp 2Stift, 2 x 18W reflector embodiment: symmetric wide distribution material: polyester resin surface: No coloring IP 66 ambient temperature: -20 ° C ... 40 ° C voltage: 220 V -10%. .. 254 V + 10%; 50/60 Hz cable entry: 2 x cable entry M25x1,5 1 x sealing plug M25x1,5 without bulb through wiring conductors 6 shutdown when opening the luminaire (mains voltage and battery circuit) with duration test)

168554

Repair kit 2x36W QTP8 Ers.QTIS-B Electronic Ballast + Accessories

168555

Repair kit 2x18W QTP8 QTISElektronisches Ers. Ballast + Accessories

1739084219

Control Pendant selection STH 6102-009

201386 8579/31-506

Switch socket 3P+N+PE 63A, 200/346-240/415V, 50+60Hz, red CCT No.: 85366990 DE Net weigth: 7,800 KG

201389 (TYPE : 8579/31-406)

Switch socket explosion-protected

201404 8146/5-V37-302-50-0050 SPARE OF TYPE : 8537/2-302-7000; 8537/2-702-7000

(Safety Switches 16 A explosion-protected Rated operational voltage AC : 400 V Rated operational current : 16 A Enclosure material : Polyester resin glass fibre-reinforced Detailed number of poles : 3 P Auxiliary contact NC : without Auxiliary contact NO : 1 NO lagging Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex de IIC T6 Gb Dust explosion protection : II 2 D Ex tb IIIC 80 °C Db Min. ambient temperature : -40 °C Max. ambient temperature : +51 °C Special conditions for extended ambient temperature, see operating instructions: Extended min. ambient temp. : -40 °C Extended max. ambient temp. : +69 °C Type of protection (IP) : IP66 Colour of handle : standard black Cable gland : 2 x M25 Ø 7 ... 17 mm 1 x M20 Ø 6 ... 13 mm Connection cross-section : 2,5 ... 6 mm2 Connection cross-section aux.: 1,5 ... 4 mm2 finely-stranded 1,5 ... 6 mm2 solid CCT No.: 85365080 DE Net weigth: 1,590 KG)

203478

6141/61-16 Hand lamp with LED Hand Lamp Series 6141/6, explosion protected Rated data: 3 V Batteries: Hand lamps are supplied with batteries. For other battery types see operating instructions For use in: Zones 1 & 2, 21 & 22

203970

Fibre optic top piece for 6141/61-16

204142

Accessories Belt case for handlamp 6141 Size 1

205308

YO3/ISC/T4 ATX YO3 Hupe Ex i ATEX, T4

Other Category Brands

Contact us for request