BRAND | Ascon |
Product | XS-3000 |
Description | Digital controller series XS (unconfigured) |
Internal code | IMP4528279 |
Custom code | 90328900 |
Technical specification | XS series (unconfigured) Supply voltage: 100... 240V, 50/60 Hz serial interface: none Auxiliary output Y4: without Setpoint: fixed value regulator - 1 internal set point and - 4 stored or 1 external set point (4-20 mA or 0-10 V) inputs: - Pt100, thermocouple (J, L, K, S, R), - Standard signal 0 (4)... 20 mA or 0... (1) 10 V - 3 logic inputs or optionally - 1 ext. setpoint input Control output Y1: Relay, logic or continuous (4... 20 mA or 0... 10 V) Control behavior: - 2-point (heating or cooling) or - 3-point (heating/cooling, PID, PI, PD, P) Auxiliary output Y2, Y3: alarm relay - Can be configured as a deviation, band, limit or loop break alarm Dimensions: 96*48 mm (DIN), depth 150 mm Degree of protection: front IP54 default: - 24 V voltage output for ext. transmitter - Handheld device (manual manipulated variable presetting) - Auto-tune and expert tune - CE mark options: - serial interface - Continuous output (setpoint or actual value, 4... 20 mA or 0... 10 V) - Program controller with (1 program with 11 segments) - IP65 front protection |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Ascon - XS-3000 Digital controller series XS (unconfigured) number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Spain Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Temperature controllers M3
(Temperature controller series M3 (unconfigured) G.Nr .: A.Nr .: Supply voltage: 85 ... 265 V ~ Output OP1 / 3: relay (2A / 250V contact) Output OP2: relay (2A / 250V contact) or logic (0 / 5VDC, 30mA) not galv. isolated adjustable via internal jumpers Output OP4: no Serial interface: no Interface protocol: no Transmitter supply: no Setpoint / Special Function: Without Manual: German / English Front color: dark gray can be configured as follows: Input: PT100; Thermocouple L, J, T, K, S; 0 (10) ... 50 mV DC, 0 (4) ... 20mA via shunt OP1 output: control or alarm output Output OP2: control or alarm output Output OP3: alarm output Output OP4: actual value or setpoint output (optional) Control: ON / OFF, or PID, heating or cooling Assignment: 1 output to the control unit and 1 output as an alarm o. both outputs as an alarm Options: current transformer input, transmitter supply, Analog Output (PV))
Temperaturregler Serie M3 (unkonfig)
Transmitterversorgung und Analog-Ausgang
temperature controller
thermostat
thermostat
Thermostat M4 Series (unkonfigueriert) Power supply 85 ... 265V Output OP1 / 3 relay (2A / 250V NO) OP2 output relay (2A / 250V NO) or logic (o / 5 VDC, 30 mA) is not electrically isolated. separately adjustable by internal jumpers OP4 output current output 0 (4) ... 20mA 750O hm / 15Vmax galv.getrennt / 500V / 1min Serial interface without Interface protocol without Transmitter supply (TV) 18 V konfiguiert be free can as follows: Input PT100, thermocouple L, J, T, K, S 0 (10) ... 50 mV DC, 0 (4) ... 20 mA via shunt Output OP1 rule or alarm output Output OP2 rule or alarm output Output OP4 control output 0/4 ... 20 mA Rmax 750R ON / OFF control or PID, heating or cules Assignment 1 output to the control unit and 1 output from alarm
(Controller / program controller series M5-3100-1200 A-No .: G-No .: Front: 48 x 48 mm Supply voltage: 100 ... 240 V, 50/60 Hz Logic inputs: 2 Auxiliary input: no Output OP1: relay (2A / 250V contact) Output OP2: relay (2A / 250V contact) Output OP3: relay (2A / 250V contact) Serial interface: no Interface protocol: no Actual value OP4: no Front color: dark gray Setpoint program: up to 16 segments can be configured as follows: Input: PT100; Thermocouple J, L, T, K, S, R, T; 0 ... 50 mV DC 0 (1) .... 5 V DC; 0 .... 10V DC, 0 (4) ... 20 mA Control: ON / OFF, PID, heating or cooling, Heating / cooling, 3 pt step Options: ext. Setpoint, current transformer Entrance, continuous control output, or serial interface)
.Regler Series M5-3101-0200 (unkonfiguriert)
Rules, unkonfiguriert
Rules Series M5-3101-0200 (unkonfiguriert)
Policy
.regler
HEAT INDICATOR
user manual in English only (Gewicht 250g)
regulator Type: M9-3151-0000 / AHL Case dimensions: 48 x 48 mm Power supply: 100 ... 240V AC with 2 relay outputs Serial interface RS485 + IPOT
Policy
regulator Case dimensions: 48 x 48 mm Power supply: 90 ... 240 VAC
Configuration 99/99 Power supply 100/240V
(Digital Controls MS (series unconfigured) - Power supply voltage: 100 ... 240V, 50/60 Hz - Serial interface: 2-wire TTY, ASCII optinoal - Dimensions: 48 x 48 mm DIN, depth 110 mm - Weight approx 200 g - input (configurable): * Pt100 * Thermocouple (L, J, K, S) * Standard signal 0 (4) ... 20 mA or 0 ... 1 (10) V Exit: * Main output Y1: relay or logic * Auxiliary output Y2: Alarm relay - PID control with self-optimization and setpoint ramp - heating or cooling characteristic with alarm output or Heating / cooling characteristic without alarm output configurable - Simultaneous display of set and actual values - control output configurable as relays or logic signal - ramp function - Power limitation - scalable inputs for standard signals - configuration via front keys - Voltage output for external 24 V - Transmitter - Parameter lock - Front protection: IP 54, with transparent cover IP 65 (optional) - Customs number: 9032/1020)
(Digital Controls MS (series unconfigured)
Digital controller